Issue: - While executing “Desktop Start” in Process Studio we get an error as mentioned below, even though the Desktop Port was Specified. 2021-05-04 18:16:55 WF_GetLstFIles - Desktop Start INFO Start:79 - desktop runtime port for agent:: null ...
Problem Statement: Desktop license not working in process-studio. Throwing below error after running Start_Dashboard.bat file Steps To Reproduce: - Edit the userdata.properties file ...
Solution: - To configure the proxy settings in desktop plugin, goto the process-studio-5.6.0\psplugins\DesktopPlugins\desktop-engine\userdata\config or aeagent\psplugins\DesktopPlugins\desktop-engine\userdata\config folder. - Edit the ...
Solution: - Goto the process-studio-5.6.0\psplugins\DesktopPlugins\desktop-engine\windows\bin or ae-agent\psplugins\DesktopPlugins\desktop-engine\windows\bin folder - Check SahiWin.exe and SahiWin.exe.config files from this location. - Remove the ...
Issue: Desktop license not working at the agent side. Solution: 1. First check whether you are applied the Product license or Runner license on the agent side. We can apply for only Runner license at the agent, product license will not work on the ...
Issue: Facing an "Invalid desktop license" issue after applying the license on desktop-spy and desktop-engine folder. Solution: 1. Check does process-studio directory structure contains any space? If yes, remove the space and then try. 2. To check ...
Issue: Facing an issue while spying the element of JAVA-applet/JNLP pages using desktop-spy. Solution: To spy the element of the JAVA-applet/JNLP pages, you need to enable the below settings. Please follow the below steps: 1. Open the ...
Solution: To spy the JAVA-applet/JNLP pages using desktop-spy, you need to enable the below settings: 1. Open the download_contenttypes.txt from "Process-studio/psplugins/DesktopPlugins/desktop-spy/userdata/config" folder. 2. Uncomment the options ...
ERROR: Resolution Please remove all the spaces from the Process studio path and go through the below prerequisites link. https://support.automationedge.com/portal/en/kb/articles/prerequisites
ERROR: Resolution: 1. Open Process studio system path location on your system \process-studio-5.6.0\psplugins\DesktopPlugins\.desk 2.Edit the .desk file and change below parameter. ae.check_.NET_version=false
Prerequisites: Windows Operating System Install JDK and set JAVA_HOME, JRE_HOME environment variables. Windows .NET framework 4.6 and above Process studio distribution full pathname should not have any spaces. Chrome browser is required to run ...
ERROR: Step by Step resolution: ProcessStudio Replace \lib\sahi-8.0-xxxx.jar with attached sahi.jar or with \psplugins\DesktopPlugins\lib\sahi.jar AutomationEdge Agent Replace \lib\sahirunner-8.0-xxxx.jar with attached sahirunner.jar Note: Remove the ...